Speak to an engineer today! 214.926.4950

Shop

Shipping fulfilment powered by Instrumart logo

  • TEX-FLO10 Flow Rate Dual Totalizer: NPN, PNP, TTL, Namur, Tacho or Closed Contact

    6 Digit Panel Meter/Controller

    TEX-FLO10 (High Voltage)

    CUSTOMIZABLE PRODUCT: This product is available in custom configurations for OEMs and high volume orders (over 100 pieces). If you have a difficult application that requires our engineering input, please call 1-888-652-4757 so we can assist you.

    Power Supply (Please Select)
    • 2x Relay Outputs $   Out of stock

    • 4x Relay Outputs $   Out of stock

    • 4-20mA / 0-10V $   Out of stock

    • RS232 (RJ Terminal) $   Out of stock

    • RS485 (Screw Terminal) $   Out of stock

    What it does:
    Accepts digital pulse inputs from flow sensors and meters. Displays the flow rate information and in-built totalizers convert the rate into volume.

    This dual totalizer flow rate controller accepts a wide range of industrial pulse and frequency flow sensor types, and is ideal for a variety of flow applications including water treatment, irrigation and level control systems.

    • Signal averaging
    • Dual totalizers with low-flow cutoff and rollover functions
    • Batching feature
    • Volumetric pulse on Total 2 with adjustable pulse width
    • Simple, intuitive interface with scrolling text prompts
    • Security PIN protected setup
    TEX-FLO10-HV, TEX-FLO10-HV-A, TEX-FLO10-HV-A-S2R, TEX-FLO10-HV-A-S4S, TEX-FLO10-HV-R2, TEX-FLO10-HV-R2-A, TEX-FLO10-HV-R2-A-S2R, TEX-FLO10-HV-R2-A-S4S, TEX-FLO10-HV-R2-S2R, TEX-FLO10-HV-R2-S4S, TEX-FLO10-HV-S2R, TEX-FLO10-HV-S4S, TEX-FLO10-HV-R4, TEX-FLO10-HV-R4-A, TEX-FLO10-HV-R4-A-S2R, TEX-FLO10-HV-R4-A-S4S, TEX-FLO10-HV-R4-S2R, TEX-FLO10-HV-R4-S4S, TEX-FLO10-A-HV, TEX-FLO10-AS-HV, TEX-FLO10-R2-HV, TEX-FLO10-R2A-HV, TEX-FLO10-R2AS-HV, TEX-FLO10-R2S-HV, TEX-FLO10-S2R-HV, TEX-FLO10-S4S-HV, TEX-FLO10-R4-HV, TEX-FLO10-R4A-HV, TEX-FLO10-R4AS-HV, TEX-FLO10-R4S-HV, TEX-FLO10-S-HV, TEX-FLO10-LV, TEX-FLO10-LV-A, TEX-FLO10-LV-A-S2R, TEX-FLO10-LV-A-S4S, TEX-FLO10-LV-R2, TEX-FLO10-LV-R2-A, TEX-FLO10-LV-R2-A-S2R, TEX-FLO10-LV-R2-A-S4S, TEX-FLO10-LV-R2-S2R, TEX-FLO10-LV-R2-S4S, TEX-FLO10-LV-S2R, TEX-FLO10-LV-S4S, TEX-FLO10-LV-R4, TEX-FLO10-LV-R4-A, TEX-FLO10-LV-R4-A-S2R, TEX-FLO10-LV-R4-A-S4S, TEX-FLO10-LV-R4-S2R, TEX-FLO10-LV-R4-S4S, TEX-FLO10-A-LV, TEX-FLO10-AS-LV, TEX-FLO10-R2-LV, TEX-FLO10-R2A-LV, TEX-FLO10-R2AS-LV, TEX-FLO10-R2S-LV, TEX-FLO10-S2R-LV, TEX-FLO10-S4S-LV, TEX-FLO10-R4-LV, TEX-FLO10-R4A-LV, TEX-FLO10-R4AS-LV, TEX-FLO10-R4S-LV, TEX-FLO10-S-LV
    RCM
    CE
    Modbus Member
    Input
     
    Sensor input
    NPN, PNP, TTL, namur, tacho or closed contact
    Excitation
    24V DC (50mA max)
    Accuracy
    0.005%
    Ambient drift
    Typically 2ppm/°C
    Flow rate
    /sec, /min or /hour
    Flow resolution
    1, 0.1, 0.01 or 0.001
    K Factor ranges
    0.1 to 99.9999/999.999/9999.99
    Totalizers
    Dual totalizers.
    Reset via front panel or rear pins. Individually programmable for low flow cutoff and rollover. Volumetric pulse on Total 2, with adjustable pulse width from 0.1 to 10.0 seconds.
    Totalizer resolution
    x0.1, x1, x10, x100 or cubic meters
    Noise filtering
    0.2, 2, 20kHz or Off
    Input frequency
    2Hz to 10KHz
    Power
     
    Power supply
    HV: 85–265V AC / 95–370V DC, or LV: 15–48V AC / 10–72V DC
    Relay Output
     
    Number of relay outputs
    None, 2 or 4
    Relay output type
    5A form A (3A 240V AC max or 3A 30V DC max)
    Analog Output (Retransmission)
     
    Number of analog outputs
    None or 1
    Analog output type
    Isolated 16 bit 4–20mA/0–10V
    Features
    Window programmable over any range within the full scale range of the controller
    Comm Port(s)
     
    Number of comm ports
    None or 1
    Serial port configuration
    Isolated RS232 (screw terminal) or RS485 (RJ11 terminal)
    Output mode
    Define ASCII, Modbus/RTU slave or Ranger A
    Baud rates
    300-38400 baud
    Parity
    Odd, even, or none
    Programming
     
    Front panel buttons
    Up, Down, P (Prog/Enter), plus 2x Function Buttons for menu access
    Display
     
    Display type
    LED display, 5 buttons
    LED indicators
    6 setpoint indicator LEDs
    Digits
    1 row of 6 digits, 0.5" (13mm), 14 segment alphanumeric LED
    Construction
     
    Casing
    Panel mount case
    Ingress protection rating
    IP65 dust/splash proof (face only)
    Dimensions (H x W x D)
    1.89 x 3.78 x 4.72" (48 x 96 x 120mm)
    Cutout area
    1.77 x 3.62" (45.5 x 92.5mm)

    TEX-FLO10 Manual TEX-FLO10 Manual 16V03, 16-May-2016 | (511 KB)

    TEX-FLO10
    -HV 85-265V AC / 95-370V DC
    -LV 15-48V AC / 10-72V DC
    Relay Output
      None
    -R2 2 x relay outputs
    -R4 4 x relay outputs
    Analog Output
      None
    -A 1 x 4-20mA/0-10V analog output
    Comms
      None
    -S2R 1 x RS232 serial port (RJ11 terminal)
    -S4S 1 x RS485 serial port (screw terminal)
    Sample order codes: TEX-FLO10-LV, TEX-FLO10-HV-R4-A-S2R
    TEX-FLO10 (High Voltage)

All prices are in US Dollars. For pricing in other currencies, please contact us.