Speak to an engineer today! 214.926.4950

IoT Gateways

Shipping fulfilment powered by Instrumart logo

  • Nimbus Smart Relay and IIoT Cloud Interface

    Nimbus Smart Relay

    CUSTOMIZABLE PRODUCT: This product is available in custom configurations for OEMs and high volume orders (over 100 pieces). If you have a difficult application that requires our engineering input, please call 1-888-652-4757 so we can assist you.

    What it does: Uses relays to control mains powered equipment, can connect to the IoT Cloud.

    Control small machines and send data to the Cloud

    The Nimbus is an all-in-one solution for controlling small machines. The conveniently compact unit measures only 3.98” x 0.91” x 4.72” and provides 3 programmable relay outputs capable of switching mains powered equipment. It features industrial grade analog and digital I/O, with 4–20mA and NTC temperature inputs.

    Collect operating data from your machine

    Additionally, the Nimbus has a built-in Cloud interface so you can send data from your machine to the Cloud – useful for scheduling maintenance, replenishing consumables and other “upkeep” tasks.

    CUSTOMIZABLE PRODUCT: This product is available in custom configurations for OEMs and high volume orders (over 100 pieces). If you have a difficult application that requires our engineering input, please call 1-888-652-4757 so we can assist you.

    Connect to whatever

    Nimbus supports a wide range of communication protocols including Modbus and MQTT. Physical connections include RS485, RS232 and Bluetooth*.

    GET THE DATASHEET

    Nimbus Datasheet Nimbus Datasheet 17V06, 03-May-2018 | (297 KB)

    In addition to this software a Bridge Key is required for the configuration of this product. You must order one unless you already have one from a previous product purchase.


    RCM
    CE
    Modbus Member
    Input
     
    Number of input channels
    2
    Input configuration
    2x 4-20mA or 1x 4-20mA and 1x NTC 10K
    Input isolation
    Not isolated
    Excitation
    24V
    Sampling rate
    1Hz
    Resolution
    12 bits
    Power
     
    Power supply
    24V DC
    General Specifications
     
    Noise immunity
    (CMRR) 160dB tested at 300V RMS 50Hz
    RF immunity
    <±1% effect FSO typical
    Linearity & repeatability
    <±0.1% FSO
    Current Input
     
    Range
    0–20mA, 4–20mA
    Input impedance
    45Ω
    Max over-range
    Protected by PTC to 24V DC
    Linearity & repeatability
    0.1% FSO max
    Accuracy
    0.1% FSO max
    Channel separation
    0.001% max
    Ambient drift
    0.003%/°C FSO typical
    Relay Output
     
    Number of relay outputs
    3
    Relay output type
    1x 16A 240VAC (form C) + 2x 7A 240VAC (form A)
    Comm Port(s)
     
    Number of comm ports
    1
    Port 1
    RS485/RS232
    RS485/422 isolation
    Yes
    Digital Inputs
     
    Number of digital inputs
    4
    Digital input type
    Open collector (NPN, PNP), TTL or Clean Contact
    Frequency range
    0–2500.0Hz
    Threshold
    1.65V
    Isolation
    No
    Data Logging
     
    Real-time clock
    Battery backed RTC (Optional)
    Data logging
    32,000 Samples
    Programming
     
    USB programmable
    Via 'PC Setup' port using Bridge Key USB programmer (sold separately)
    Define WorkBench
    Simple configuration and datalog retrieval using Define WorkBench
    Construction
     
    Casing
    DIN 22 rail mounting; Material: ABS inflammability V0 (UL94)
    Dimensions (H x W x D)
    3.98 x 0.87 x 4.72" (101 x 22 x 120mm)
    Environmental Conditions
     
    Operating temperature
    –40 to 176°F (–40 to 80°C)
    Storage temperature
    –40 to 176°F (–40 to 80°C)
    Operating humidity
    5–85% RH max, non-condensing
    Certifications & Compliances
     
    EN 61326-1
    :2006
    EMC
    Emissions EN 558022-A; Immunity EN 50082-1; Safety EN 60950

    Nimbus Manual Nimbus Manual 18v2, 11-Mar-2019 | (1449 KB)

    Nimbus Datasheet Nimbus Datasheet 17V06, 03-May-2018 | (297 KB)

    Define WorkBench

    Define WorkBench

    Simple software to program your Zen series device

    Use Define WorkBench to simulate, configure and view data for all Zen series control stations, including:

    With a user-friendly, uncluttered design, WorkBench offers a simple interface for setting up and scaling your Zen unit, as well as retrieving and graphing your datalog.

    N.B. Version 2 features Simulation Mode and is only compatible with legacy ZEN-16 firmware 2.0.0 and later.

    NIM
    Channels
    -2A 2 x RS485 / RS232
    -AT 1 x RS485 / RS232, 1 x NTC
    Comms Configuration
    -RTC
    Real Time Clock
    Sample order codes: NIM-AT, NIM-AT-RTC, NIM-2A, NIM-2A-RTC

    NOTE: Bluetooth and Modbus TCP comms are also supported by this instrument and are offered to OEM's, subject to minimum order requirements.Please contact us to inquire about these options.

    Accessories/Software
    Bridge Key USB Bridge Key and communications kit (Sold separately)
    GT-HE910-NAD GateTel cellular modem for 3G/4G connections (Sold separately)
    Define WorkBench Simple utility for setting up your Nimbus

    Nimbus Smart Relay